ANSIAGMAB96RSpecification for Measurement of Linear Vibration on Gear Units-. AGMA B96 (R). Specification for Measurement of Linear Vibration on Gear Units. standard by American Gear Manufacturers. The ANSI/AGMA B96 give the acceleration limits VS frequency chart but I need to have an exact formula in order to calculate these limits.

Author: Kazigar Keshura
Country: Morocco
Language: English (Spanish)
Genre: Video
Published (Last): 4 May 2016
Pages: 76
PDF File Size: 7.75 Mb
ePub File Size: 10.68 Mb
ISBN: 165-7-99782-337-6
Downloads: 89273
Price: Free* [*Free Regsitration Required]
Uploader: Shaktigami

SCOPE This standard presents a method for measuring steady state filtered linear vibrations of a gear unit.

Types of instrumentation, measurement methods, and testing procedures for the determination of linear vibration levels for specific types of gear units are provided. Vibration limits at discrete frequencies are recommended for acceptance testing. It is not the intent of this standard to provide unfiltered limits. This standard does not apply to integrated systems, shaft-mounted units, special or auxiliary drive trains or power take-off gears.

6000-b966

Vibration amplitudes exceeding the recommendations of this specification for drives with flexible housings or on flexible supports may also be allowable if accounted for in the design. Acceptable limits for this type of equipment should be independently specified.

  DEBORAH SCHIFFRIN APPROACHES TO DISCOURSE PDF

However, if negotiated, this standard may be applied to such equipment. Performance of driven equipment is dependent upon the individual characteristics of the prime mover, gear unit, driven machine and support structure, as well as their combined effects as a system. The proper assessment of performance characteristics is essential for realistic evaluation. The knowledge and judgment required to properly evaluate the gear unit vibration comes primarily from years of accumulated experience in designing, manufacturing, and operating gear units.

For these reasons, the use of this standard and the evaluation of test results for specific gear product applications should only be attempted by experienced personnel.

The complexity of gear vibration phenomena makes most vibration standards difficult to apply or to properly interpret. The purpose was, also, to encourage the maximum practical degree of uniformity and consistency among vibration measurement practices within the gear industry.

The revision includes clarification of application of the standard, changes to annex A, and the addition of a new annex C, from ISO Suggestions for improvement of this standard will be welcome.

  HDMI SPECIFICATION 1.3A PDF

Vibration limits calculation according to the ANSI/AGMA 6000-B96 | AMP Maintenance Forums

Torsional and transient vibrations of a geared system are not included in this standard. Five annexes are for reference only and are not a part of this standard. Annex A illustrates the relationship between vibratory displacement, velocity and acceleration waveforms.

Annex B discusses systems effects and responsibility. Annex C presents five classes of gear unit vibration rating and a subjective procedure for selecting the proper rating based on the application and transmitted power.

ANSI/AGMA B96 (R) – Specification for Measurement of Linear Vibration on Gear Units

Annex D gives the conversion of metric, SI units to non-metric inch units. Annex E contains a bibliography.